Chapter 4: List of function parameters - shorted
53
0: Control via the operation panel
1: Control via input terminals
2: Control via PC
.X (frequency source)
0: Main source of frequency
1: X and Y operations (operating mode
specified by dozens)
2: Switch between X and Y
3: Switch between X and "X and Y"
4: Switching between Y and "X and Y"
X. (X and Y operations)
0: X + Y
1: X-Y
2: Maximum X and Y
3: Minimum X and Y
Select the main
frequency source X
0: Digital setting (P0.10 preset
frequency, can change over UP / DOWN)
1: Digital setting (P0.10 preset
frequency, can change over UP / DOWN)
2: FIV
3: FIC
4: By the rotary knob on the panel
5: Impulse setting (S3), option
6: Step speeds
7: Simple PLC
8: PID
9: Communication interface
Select the auxiliary
frequency source Y
The same like P0.04 (selection of the
main X source)
0 - 9
Select the range of
auxiliary frequency
source Y
0: Considering to the maximum
frequency
1: Considering to the maximum
frequency of X source
Extension of
auxiliary frequency
source Y