Chapter 4: List of function parameters - shorted
54
P0.08
Acceleration time 1
0.00s – 65000 s
by the
model
☆
P0.09
Deceleration time 1
0.00s – 65000 s
by the
model
☆
P0.10
Default frequency
0.00 - maximum frequency (P0.12)
50.00Hz
☆
P0.11
Direction of rotation
0: The same direction
1: Reverse direction
0
☆
P0.12
Maximum
frequency
50.00 Hz - 3200.00 Hz
50.00Hz
★
P0.13
The upper limit of
the frequency
source
0: P0.12
1: FIV
2: FIC
3: Reserved
4: Impulse setting
5: Setting via the communication input
0
★
P0.14
The upper limit of
the frequency
Bottom frequency limit P0.16 -
maximum frequency P0.12
50.00Hz
☆
P0.15
The upper limit of
the frequency - shift
0.00 Hz- maximum frequency P0.12
0.00Hz
☆
P0.16
Bottom frequency
limit
0.00 Hz - Upper frequency limit P0.14
0.00Hz
☆
P0.17
Carrier frequency
1 kHz-16.0 kHz
by the
model
model
☆
P0.18
The influence of
temperature on the
carrier frequency
0: No
1: Yes
1
☆
P0.19
Time increment for
acceleration /
deceleration
0: 1 s
1: 0.1 s
2: 0.01 s
1
★
P0.21
Frequency shift of
auxiliary frequency
source for X and Y
operation
0.00 Hz – maximum frequency P0.12
0.00Hz
☆