BA 1001/1501/2001 us – Edition 3.3 * 12001b330.fm 3-17
Operation
• Do not run the starter for more than 10 seconds
• Wait about 1 minute so the battery can recover before trying again
Procedure
After you have completed the starting preparations:
☞Insert the starting key in preheating start switch 3
☞Turn the starting key to position “1”
☞Check whether the following indicator lights illuminate:
➥Indicator light 9 for engine oil pressure
➥Indicator light 13 for alternator charge function
☞Replace malfunctioning indicator lights immediately.
☞Turn the starting key to position “2” and hold it in this position until the preheating indi-
cator light goes out
☞Turn the starting key to position “3” and hold it in this position until the engine starts
➥If the engine does not start after 10 seconds
☞Interrupt the start procedure and try again after 1 minute
➥If the engine still does not start after the second try
☞Contact a Wacker Neuson service center for troubleshooting.
➥As soon as the engine runs:
☞Release the starting key
When the engine runs smoothly (increased engine speed):
1
0
2
3
Fig. 27: Preheating start switch
3
Fig. 28: Indicator lights
9
13