EasyManua.ls Logo

Wacker Neuson 2001

Wacker Neuson 2001
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-18 BA 1001/1501/2001 us – Edition 3.3 * * 12001b330.fm
Operation
3.14 Travel interlock
Scope of delivery
A: starting key (blue, 2 pieces)
B: master key (red)
Important
Keys can be coded or deleted only with the master key. A new travel interlock
must be installed if the master key is lost.
Coding keys
1 Insert the master key in the starter and turn it to position 1 for a maximum 5 seconds.
2 Remove the master key.
3 Turn the keys requiring coding to position 1 within 15 seconds, for at least one second.
The key is registered.
Coding is automatically interrupted if no key is coded within 15 seconds.
Coding can be performed for a maximum 10 keys.
Deleting a key
If a coded key is lost, all keys have to be deleted and recoded.
1 Insert the master key in the starter and turn it to position 1 for at least 20 seconds.
The coded keys are deleted now. New or existing keys have to be recoded.
Fig. 29: Travel interlock key
BA
Fig. 30: Travel interlock key
1
0

Table of Contents

Related product manuals