ENTER/EXIT PROGRAMMING MODE In-Store Minimum Reads
Product Reference Guide 95
In-Store Minimum Reads
This feature specifies the minimum number of consecutive times an in-store label must be
decoded before it is accepted as good read.
In-store labels are defined as UPC-A labels with a number-system character of 2 or
4 as well as
EAN 8 and EAN 13 labels with a Flag1 character of 2 or an EAN 13 label starting with the
three characters '980'.
In-Store Minimum Reads = 1
In-Store Minimum Reads = 2
DEFAULT
In-Store Minimum Reads = 3
In-Store Minimum Reads = 4