Especificações Técnicas
Português
8.2.1 Normas Consideradas
Tabela 8.2: Normas consideradas
Normas de
segurança
UL 508C - power conversion equipment.
UL 840 - insulation coordination including clearances and creepage distances for electrical
equipment.
EN61800-5-1 - safety requirements electrical, thermal and energy.
EN 50178 - electronic equipment for use in power installations.
EN 60204-1 - safety of machinery. Electrical equipment of machines. Part 1: general requirements.
Nota: para ter uma máquina em conformidade com essa norma, o fabricante da máquina é
responsável pela instalação de um dispositivo de parada de emerncia e um equipamento
para seccionamento da rede.
EN 60146 (IEC 146) - semiconductor converters.
EN 61800-2 - adjustable speed electrical power drive systems - part 2: general requirements -
rating specifications for low voltage adjustable frequency AC power drive systems.
Normas de
compatibilidade
eletromagnética
(*)
EN 61800-3 - adjustable speed electrical power drive systems - part 3: EMC product standard
including specific test methods
EN 55011 - limits and methods of measurement of radio disturbance characteristics of industrial,
scientific and medical (ISM) radio-frequency equipment
CISPR 11 - industrial, scientific and medical (ISM) radio-frequency equipment - electromagnetic
disturbance characteristics - limits and methods of measurement
EN 61000-4-2 - electromagnetic compatibility (EMC) - part 4: testing and measurement
techniques - section 2: electrostatic discharge immunity test
EN 61000-4-3 - electromagnetic compatibility (EMC) - part 4: testing and measurement
techniques - section 3: radiated, radio-frequency, electromagnetic field immunity test.
EN 61000-4-4 - electromagnetic compatibility (EMC) - part 4: testing and measurement
techniques - section 4: electrical fast transient/burst immunity test
EN 61000-4-5 - electromagnetic compatibility (EMC) - part 4: testing and measurement
techniques - section 5: surge immunity test
EN 61000-4-6 - electromagnetic compatibility (EMC) - part 4: testing and measurement
techniques - section 6: immunity to conducted disturbances, induced by radio-frequency fields
Normas de
construção
mecânica
EN 60529 - degrees of protection provided by enclosures (IP code)
UL 50 - enclosures for electrical equipment
IEC 60721-3-3 - classification of environmental conditions
(*) Normas atendidas com instalação de filtro RFI externo. Ver Capítulo 3 INSTALAÇÃO E CONEXÃO na página 85.