Home
Wisi
Amplifier
Chameleon
Wisi Chameleon Installation Guide
82 pages
Manual
Specs
Ask a question
To Next Page
To Next Page
Loading...
Software version
2.4
.3
Installation Guide
www.
www
.
wi
si.de
2015
-
11
-16 JÅ
2
Table of Contents
Service and Support
3
Table of Contents
4
Getting Started
6
General Information about Software Options
7
Chameleon in GN50
8
The Wisiconnect.tv Portal
9
Registering the Chameleon & Downloading Software Options
10
Upgrading the Chameleon Software & Software Options
11
Connecting to the Chameleon User Interface
12
Select Operation Mode
13
Add and Configure Inputs
16
Add ASI and IP Inputs
17
Add Tuner Inputs
20
Add SDI Inputs
22
Add and Configure Outputs
22
Add and Configure Analogue Outputs
24
Add and Configure Input
25
WSS, Video Conversion and AFD
26
HD to SD Downscaling and Dual Mono
28
Add and Configure ASI, SDI, HD-SDI and FM Outputs
29
Add and Configure DVB-T, DVB-C, J.83 ANNEX B, J.83 ANNEX C, ISDB-T and DTMB Outputs
31
Add and Configure IP (SPTS/MPTS) Outputs
34
Add and Configure IP FEC Outputs
36
Streaming between Chameleons Installed in GN50
37
SERVICE MANAGEMENT, Service & PID Management
37
Navigating the Inputs and Outputs Views in Service Management
39
Navigating in the Services View in Service Management
40
Managing Services and Pids in the Inputs Part of Service Management
41
Settings and Management of Outputs in Service Management
46
Descrambling and Common Interface
52
Remultiplexing and PSI/SI
54
Service Listings and Service Types
55
Streams (Pids) and Streams/Pids Listings
56
Outputs TS DVB Network Settings
57
Outputs Services Settings
57
The System Management and DVB Network PSI/SI
58
Transmodulation and Transparent Outputs
59
Encryption - DVB-CSA Scrambling and Simulcrypt
61
Encryption - Scrambling Overview
63
Add EMM Generator Connections
64
Add EMM Connection to the Output(S)
65
Add ECM Generator Connections
65
Add SCG (Scrambling Control Group)
66
Edit Group in SCG (Set up Connection to Ecmg)
67
Connect Output Services to an SCG (to a Group)
68
Simulcrypt Menu for a Correct Set-Up
69
Settings: Managing the Chameleon Module
70
Add and Configure Network Interfaces
70
Date and Time (NTP Server Access and Time Sources)
71
Scheduler - Commands Scripting
72
Snmp
73
Sap
75
User Management - Password Protection
75
Software and Software Options (Entitlement) Upgrade
76
Module Maintenance
77
Log
79
Status Information
80
Software Options
81
Other manuals for Wisi Chameleon
Quick Guide
8 pages
Need help?
Do you have a question about the Wisi Chameleon and is the answer not in the manual?
Ask a question
Wisi Chameleon Specifications
General
Frequency Range
47 - 862 MHz
Power Supply
230 V AC, 50 Hz
Operating Temperature
-20°C to +50°C
Noise Figure
5 dB
Connectors
F-type
Related product manuals
Wisi DY 50
10 pages
Wisi VX 56 B Series
36 pages