11.2 Add EMM Generator connections
The CA Server set-up for EMM and ECM generation is not covered by this manual. Please contact your CAS supplier
for information.
The IP address to be entered in the CAS is the IP address of the Chameleon network interface used for Simulcrypt
communication.
Adding an EMM Generator connection
In the Simulcrypt menu under SETTINGS, click ADD EMM under the EMM Generators box.
1. Enter a name for the EMMg
2. Enter the Client ID (info from CAS supplier, often same as the superCAS). The Client ID should be entered as a
hex number, but without the 0x prefix. As an example, if the Client ID is given as 0x320011ac, you should enter
320011ac in the UI. The Client ID should always be 8 hex digits.
3. Select the Network interface you are using. Select a Simulcrypt enabled interface in the drop-down list, or
remain with Auto. If Auto, the Chameleon will scan all Simulcrypt enabled interfaces and check if a connection can
be established based on port and Client ID.
4. Enter the PORT (as the port stated by the CAS)
5. Optionally, enter private data
6. Set the EMM bandwidth (check with your CAS provider)
7. Click the “yellow tick”
Adding another EMM Generator connection
Repeat the steps above.
EMM Generator connection status during initialisation
After configuring the EMMg, the Chameleon will start listening for a connection to the CA server. If the connection
is established correctly, the STATUS of the EMMg is “Client connected”.