Image Quality
WorkCentre 3119 06/06 3-19
IQ 17 Defective Image Quality
Description
The copied image is excessively light or dark
Check and Cause Solution
Check shading profile Perform shading test in tech mode, GP 5.
Check the gap between original and scanner glass, PL
7.
A gap of more than 0.5mm can cause blurred images.
Ensure the cover is closed correctly.