General Procedures and Information
6-32 06/06 WorkCentre 3119
GP 5 Tech Mode
The Engine Tests Mode supplies useful functions to check the condition of the engine. It tests the
condition of each device and displays the result of the test on the LCD.
To enter the Tech Mode
To enter the Engine Test mode
Press “Menu > Copies >W > X> Menu > X in sequence, and the LCD briefly displays 'Tech
Mode', the machine has entered Engine Test Mode.
• To enter a lower menu (Sub menu) press the Start/Enter key.
• To confirm selection press the Print key.
• To exit into an upper menu press the Menu/Exit key.
• To return to the user menu press the Menu/Exit key.
Tech Mode Settings Map
Tech mode descriptions
Data Setup
This option enables you to selectively clear information stored in your machine’s memory. To ac-
cess this option, enter Tech mode and press the menu button until ’Data Setup’ appears on the
display. Press the enter button and use the W and Xbuttons to scroll between the options availa-
ble. Press the enter button to confirm selection. Or, to return to standby mode, press Stop/Clear.
-Clear all Mem. : Clears all settings and information stored in the machine’s memory accord-
ing to country.
-Total page CNT : Clears the total page printed counter.
-FLT Scan CNT : Clears the total page scanned counter.
-Used Toner CNT : Clears the total of pages printed counter:
Table 1:
1st Level 2nd Level 3rd Level 4th Level
Default
value
Tech Mode Data Setup Clear All Mem. Select country
Clear Count Total page CNT
FLT Scan CNT
Used Toner CNT
Flash Upgrade Local
Machine Test Switch Test
Dram Test
Rom Test
Pattern Test
Shading Test
Report System Data
Error Info