Status Indicator RAPs
10-600, 610 Envelope Mode Error RAP
10-600 The machine has detected that it has not switched to envelope mode.
10-610 The machine has detected that it has not switched to envelope mode.
Procedure
WARNING
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
WARNING
Do not touch the fuser while it is hot.
NOTE: The main PWB has test points. The location of the test points is shown on the Main
PWB PJ location illustration.
Refer to (4250/4260) Wiring Diagram 25 (4265) Wiring Diagram 41 . Perform the following:
1. Open the side cover assembly, PL 7.30 Item 1.
2. Check the fuser nip release mechanism. If necessary, install a new fuser assembly, PL
10.28 Item 1.
3. Check that the envelope sensor actuator on the front cam, PL 7.32 Item 9 is not missing
or damaged.
4. Enter dC330 code 07-610. Check the envelope sensor (Q07-610), PL 7.32 Item 1.
5. (4250/4260) Check the wiring between the envelope sensor and CN17 on the Main PWB.
If necessary, install a new envelope sensor, PL 7.32 Item 1.
6. (4265) Check the wiring between the envelope sensor and CN31 on the Main PWB. If
necessary, install a new envelope sensor, PL 7.32 Item 1.
7. Enter dC330 code 07-600. Check that the envelope motor (MOT07-600) runs and drives
the fuser release mechanism. Install new components as necessary, PL 7.32.
8. (4250/4260) Check the wiring between the envelope motor and CN17 on the Main PWB.
If necessary, install a new envelope motor, PL 7.32 Item 17.
9. (4265) Check the wiring between the envelope motor and CN31 on the Main PWB. If nec-
essary, install a new envelope motor, PL 7.32 Item 17.
10. Perform the OF5 Main PWB Check RAP.
10-700, 710 Fuser Fuse Warning RAP
10-700 The machine has detected that fuse F1 did not blow when a new fuser is installed.
10-710 The machine has detected a fault with either fuse F1 or F2 on the fuser.
NOTE: The fuser has 2 fusible resistors that act as a simple CRUM. Fuse F1 is blown when a
new fuser is installed, fuse F2 is blown at fuser end of life.
Procedure
WARNING
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
WARNING
Do not touch the fuser while it is hot.
Refer to Wiring Diagram 21. Perform the following:
1. Enter dC330 codes 10-700 and 10-710. Check the state of fuse F1 and fuse F2.
2. Remove, then replace the fuser assembly, PL 10.28 Item 1.
3. Install a new fuser assembly, PL 10.28 Item 1.