January 2016
4-144
WorkCentre WorkCentre 4150/4250/4260WorkCentre 4150/4250/42604150/
REP 9.6
Repairs and Adjustments
REP 9.6 Xerographic Module Connector (4265)
Parts List on PL 4.15
Removal
NOTE: This procedure should only be performed on the 4265. For other machine models, refer
to the Table of Contents.
WARNING
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
WARNING
Take care during this procedure. Sharp edges may be present that can cause injury.
CAUTION
Before performing this procedure, refer to General Disassembly Precautions, GP 10.
1. Remove the Main Drive Assembly (REP 4.3).
2. Remove the Cover (Figure 1).
Figure 1 Removing the Cover
1
Remove the four mounting screws.
2
Remove the Cover.