January 2016
4-156
WorkCentre WorkCentre 4150/4250/4260WorkCentre 4150/4250/42604150/
REP 10.6, REP 10.7
Repairs and Adjustments
Replacement
Replacement is the reverse of the removal procedure.
REP 10.7 Fuser Assembly Components (4250/4260/4265)
Parts List on PL 10.28 and PL 10.30
Purpose
This procedure is used to repair the following components:
NOTE: Only perform the steps that are necessary to repair the damaged component.
• Springs, PL 10.28 Item 7.
• Heat lamp assembly, PL 10.30 Item 13.
• Heat roller, PL 10.30 Item 10.
• Heat roller collar, PL 10.30 Item 9.
• Heat roller bearings, PL 10.30 Item 8.
• Pressure roller bearings, PL 10.30 Item 17.
• CRUM Assembly PL 10.28.
Removal
NOTE: This procedure should only be performed on the 4250/4260/4265 machines. For the
4150 procedure, refer to the table of contents.
WARNING
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
WARNING
Do not touch the fuser while it is hot.
CAUTION
Before performing this procedure, refer to General Disassembly Precautions, GP 10.
1. Remove the Fuser Assembly (REP 10.1).