03/02 How to use the Diagnostic C/E Mode
WorkCentre Pro 423/428 2-175 CHAPTER 2 TROUBLESHOOTING
Chain Functio
n
Item Min. value Default Max. value Amount
of change
Adjustment Remarks
50 133
Enable/Disable Priority Transmission Specification from
Panel
0 01 1 1 0: Disable 1: Enable
50 135
Component of ID used for controlling Relay Broadcast
Infinite Loop Prevention Function
0001 1 to 0XFFFF
50 136 Composite ESS Installation Status 0 01 1 1 0:Not installed 1:Installed
50 200 Remote Center Call ON/OFF Flag 0 01 1 1 0:OFF 1:ON
50 201 Machine Telephone Number (for Remote Maintenance) 38bytes Character String
50 202 Communication Mode for EP-Front to Machine 0 00 1 1 0:G3 1:G4
50 203 Installer·s Employee Number 00000000
00
5 bytes Character String
50 204 1Way/2Way setting 0 01 1 1 0:1Way 1:2Way
50 206 Inspection/Repair Request Function ON/OFF Flag 0 00 1 1 0:OFF 1:ON
50 207 Fixed-Time Report Count 00 1 0 to 0XFF
50 208 EP-Front Telephone number 38bytes Character String
50 209 Communication Mode for Machine to EP-Front 0 00 1 1 0:G3 1:G4
50 210 Installation Date FFFFFF 3
50 211 TEL No. of Communication Management Data Destination 38bytes Character String
50 212 Communication Mode for Machine to Communication
Management Data Destination
0 00 1 1 0:G3 1:G4
50 213 Alert Origination Function ON/OFF Flag 0 00 1 1 0:OFF 1:ON
50 214 Auto Notification Time
Shared for fixed-time notification, auto notification of paper
count data, and periodic polling.
FFFF 2 Hour and minute
50 215 Billing Notification Day 0 00 31 1 0: No notification 1-31: Notification day
50 216 Billing Notification Time (Hour and Minute) 1530 2
50 217 Paper Count Notification Interval 0 00 3 1 0: No notification 1: Daily 2: Weekly 3: Monthly
50 218 Auto Notification Date
Shared for paper count notification and periodic polling.
31 1 0X01 to 0X31(BCD expression)
50 220 Consumable Replacement
Replenishment data auto notification ON/OFF flag
0 00 1 1 0: No notification 1: Notification
50 221 Periodic Polling Notification Interval 0 00 3 1 0: No notification 1: Daily 2: Weekly 3: Monthly
50 231 System Fail or Local Fail1 Count Threshold 0A 1 0 to 0XFF (0: Not detected) Default: 10 (0X0A)