EasyManua.ls Logo

YASKAWA FSDrive-MV1000 - Fault, Alarm and Error Displays

YASKAWA FSDrive-MV1000
190 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5.3 Types of Faults, Alarms, and Errors
114 YASKAWA ELECTRIC EZZ010928 FSDrive-MV1000 Instructions
Fault, Alarm and Error Displays
Faults (Drive Faults and Power Cell Faults)
When the drive detects a fault, the code indicated by the digital operator lights continuously rather than flashing, and the
ALM indicator LED also lights continuously. A flashing indication means a minor fault or alarm; refer to Minor Faults
and Alarms on page 115 in this case. To give an example, there are two types of indication for oS (Overspeed), one
being a fault and the other a minor fault.
Table 5.6 Fault Displays (1)
Digital Operator
Display
Name Page
Digital Operator
Display
Name Page
bUS Option Communication Error 118 GF Ground Fault 123
CE
MEMOBUS/Modbus
Communication Error
118
IOV Input Overvoltage 124
LF Output Phase Loss 124
CF Control Fault 118
LIN
nn LINK FAULT
<1>
CCB-MB Communication Error
(Link Fault)
124
CFA
nn coF
<1>
Current Offset Fault 119 oFA00
Option Card Fault at Option Port
CN5-A
124
CFA
nn CUV
<1>
Undervoltage 119 oFA01, oFA02
Option Card Error Occurred at
Option Port CN5-A
124
CFA
nn FU
<1>
Fuse Blowout 119 oFA03 to oFA06
Option Card Error Occurred at
Option Port CN5-A
125
CFA
nn IGBT_FLT
<1>
IGBT Fault 119 oFA10, oFA11
Option Card Error Occurred at
Option Port CN5-A
125
CFA
nn OC
<1>
Overcurrent 119 oFA12 to oFA17
Option Card Fault at Option Port
CN5-A
125
CFA
nn OH
<1>
IGBT Overheating 120 oFA30 to oFA43
Option Card Error Occurred at
Option Port CN5-A
125
CFA
nn OH1
<1>
IGBT Overheating 1 120 oFb00
Option Card Fault at Option Port
CN5-B
125
CFA
nn OV
<1>
Overvoltage 1 120 oFb01, oFb02
Option Card Error Occurred at
Option Port CN5-B
125
CFA
nn OV2
<1>
Overvoltage 2 120 oFb03 to oFb11
Option Card Error Occurred at
Option Port CN5-B
125
CFA
nn THBOW
<1>
Thermistor Disconnect 120 oFb12 to oFb17
Option Card Fault at Option Port
CN5-B
125
CFA
nn VCF_OV
<1>
Main Circuit Capacitor Neutral
Point Potential Error
120 oFC00
Option Card Fault at Option Port
CN5-C
125
CPF00, CPF01
<2> Control Circuit Error 121
oFC01, oFC02
Option Card Error Occurred at
Option Port CN5-C
125
CPF02 A/D Conversion Error 121
CPF06 EEPROM Memory Data Error 121
oFC03 to oFC11
Option Card Error Occurred at
Option Port CN5-C
125
CPF20, CPF21
<2> Control Circuit Error 121
CPF22 Hybrid IC Error 121
oFC12 to oFC17
Option Card Fault at Option Port
CN5-C
125
CPF23 Control Board Connection Error 121
CPF26 to CPF35
Control Circuit Error 121
oL1 Motor Overload 126
CPF40 to CPF45 oL2 Drive Overload 126
dEv
Speed Deviation (for Control Mode
with PG)
121
oL3 Overtorque Detection 1 126
oL4 Overtorque Detection 2 127
EF0 Option Card External Fault 122 oL5 Mechanical Weakening Detection 1 127
EF1 to EF16 External Fault (input terminal) 122 OOV Output Overvoltage 127
Err EEPROM Write Error 123 oPr Digital Operator Connection Fault 127
FAn Fan Fault 123
oS
Overspeed
(for Control Mode with PG)
127
FbH Excessive PID Feedback 123
FbL PID Feedback Loss 123 PGo
PG Disconnect
(for Control Mode with PG)
127

Table of Contents