12.3  Warning Displays
 12.3.2  Troubleshooting Warnings
12-55
A.93B: 
Overheat Warning
The surrounding 
temperature is too 
high.
Check the surrounding 
temperature using a 
thermostat.
Lower the surrounding tem-
perature by improving the 
installation conditions of the 
Linear Servomotor or the 
machine.
–
Operation was 
performed under 
an excessive load.
Use the accumulated 
load ratio to check the 
load during operation.
Reconsider the load and 
operating conditions.
–
A failure occurred 
in the SERVO-
PACK.
–
The SERVOPACK may be 
faulty. Replace the SERVO-
PACK.
–
The temperature 
detection circuit in 
the Linear Servo-
motor is faulty or 
the sensor 
attached to the 
machine is faulty.
–
The temperature detection 
circuit in the Linear Servo-
motor may be faulty or the 
sensor attached to the 
machine may be faulty. 
Replace the Linear Servo-
motor or repair the sensor 
attached to the machine.
–
A.942: 
Speed Ripple Com-
pensation Informa-
tion Disagreement
The speed ripple 
compensation 
information stored 
in the encoder 
does not agree 
with the speed 
ripple compensa-
tion information 
stored in the 
SERVOPACK.
–
Reset the speed ripple 
compensation value on the 
SigmaWin+.
page 8-60
–
Set Pn423 to n.1 (Do 
not detect A.942 alarms). 
However, changing the set-
ting may increase the speed 
ripple.
page 8-60
–
Set Pn423 to n.0 
(Disable speed ripple com-
pensation). However, 
changing the setting may 
increase the speed ripple.
page 8-60
A.94A: 
Data Setting Warn-
ing 1 (Parameter 
Number Error)
An invalid param-
eter number was 
used.
Check the command 
that caused the warn-
ing.
Use the correct parameter 
number.
page 12-
58
A.94b: 
Data Setting Warn-
ing 2 (Out of Range)
The set com-
mand data was 
clamped to the 
minimum or maxi-
mum value of the 
setting range.
Check the command 
that caused the warn-
ing.
Set the parameter within 
the setting range.
page 12-
58
A.94C: 
Data Setting Warn-
ing 3 (Calculation 
Error)
The calculation 
result of the set-
ting is not correct.
Check the command 
that caused the warn-
ing.
Set the parameter within 
the setting range.
page 12-
58
A.94d: 
Data Setting Warn-
ing 4 (Parameter 
Size)
The parameter 
size set in the 
command is not 
correct.
Check the command 
that caused the warn-
ing.
Set the correct parameter 
size.
page 12-
58
A.94E: 
Data Setting Warn-
ing 5 (Latch Mode 
Error)
A latch mode error 
was detected.
Check the command 
that caused the warn-
ing.
Change the setting of 
Pn850 or the LT_MOD data 
for the LTMOD_ON com-
mand sent by the host con-
troller to an appropriate 
value.
(The applies when using the 
MECHATROLINK-II-com-
patible profile.)
page 12-
58
Continued on next page.
Continued from previous page.
Warning Number: 
Warning Name
Possible Cause Confirmation Correction Reference