No.
n.X
/NEAR (Near Output) Signal Allocation Reference
0 Disabled (the above signal output is not used).
page 6-13
1 Output the signal from the CN1-1 or CN1-2 output terminal.
2 Output the signal from the CN1-23 or CN1-24 output terminal.
3 Output the signal from the CN1-25 or CN1-26 output terminal.
4 to 6 Reserved settings (Do not use.)
n.X Reserved parameter (Do not change.)
n.X Reserved parameter (Do not change.)
n.X Reserved parameter (Do not change.)
n.X
/DEC (Origin Return Deceleration Switch Input) Signal Allocation
0 Active when CN1-13 input signal is ON (closed).
1 Active when CN1-7 input signal is ON (closed).
2 Active when CN1-8 input signal is ON (closed).
3 Active when CN1-9 input signal is ON (closed).
4 Active when CN1-10 input signal is ON (closed).
5 Active when CN1-11 input signal is ON (closed).
6 Active when CN1-12 input signal is ON (closed).
7 The signal is always active.
8 The signal is always inactive.
9 Active when CN1-13 input signal is OFF (open).
A Active when CN1-7 input signal is OFF (open).
B Active when CN1-8 input signal is OFF (open).
C Active when CN1-9 input signal is OFF (open).
D Active when CN1-10 input signal is OFF (open).
E Active when CN1-11 input signal is OFF (open).
F Active when CN1-12 input signal is OFF (open).
n.X
/EXT1 (External Latch Input 1) Signal Allocation
0 to 3 The signal is always inactive.
4 Active when CN1-10 input signal is ON (closed).
5 Active when CN1-11 input signal is ON (closed).
6 Active when CN1-12 input signal is ON (closed).
D Active when CN1-10 input signal is OFF (open).
E Active when CN1-11 input signal is OFF (open).
F Active when CN1-12 input signal is OFF (open).
7 to C The signal is always inactive.
n.X
/EXT2 (External Latch Input 2) Signal Allocation
0 to F
The allocations are the same as the /EXT1 (External Latch Input 1) signal allo-
cations.
n.X
/EXT3 (External Latch Input 3) Signal Allocation
0 to F
The allocations are the same as the /EXT1 (External Latch Input 1) signal allo-
cations.