13.1 List of Servo Parameters
13.1.2 List of Servo Parameters
13-24
Pn512
2
Output Signal Inverse
Settings
0000h to
1111h
0000h All
After
restart
Setup
page
6-6
Pn514
2
Output Signal Selec-
tions 4
0000h to
0666h
0000h All
After
restart
Setup
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.X
Output Signal Inversion for CN1-1 and CN1-2 Terminals
0 The signal is not inverted.
1 The signal is inverted.
n.X
Output Signal Inversion for CN1-23 and CN1-24 Terminals
0 The signal is not inverted.
1 The signal is inverted.
n.X
Output Signal Inversion for CN1-25 and CN1-26 Terminals
0 The signal is not inverted.
1 The signal is inverted.
n.X Reserved parameter (Do not change.)
n.X Reserved parameter (Do not change.)
n.X Reserved parameter (Do not change.)
n.X
/PM (Preventative Maintenance Output) Signal Allocation Reference
0 Disabled (the above signal output is not used).
page 9-15
1 Output the signal from the CN1-1 or CN1-2 output terminal.
2 Output the signal from the CN1-23 or CN1-24 output terminal.
3 Output the signal from the CN1-25 or CN1-26 output terminal.
4 to 6 Reserved settings (Do not use.)
n.X Reserved parameter (Do not change.)