13.1 List of Servo Parameters
13.1.2 List of Servo Parameters
13-28
Pn61A
2
Overheat Protection
Selections
0000h to
0003h
– 0000h Linear
After
restart
Setup
page
6-62
Pn61B
*8
2 Overheat Alarm Level 0 to 500 0.01 V 250 All
Immedi-
ately
Setup
page
6-63
Pn61C
*8
2 Overheat Warning Level 0 to 100 1% 100 All
Immedi-
ately
Setup
page
6-63
Pn61D
*8
2
Overheat Alarm Filter
Time
0 to 65,535 1 s 0 All
Immedi-
ately
Setup
page
6-63
Pn621 to
Pn628
*3
–
Safety Module-Related
Parameters
–––All–––
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X Overheat Protection Selection
0 Disable overheat protection.
1
Use overheat protection in the Yaskawa Linear Servomotor.
*7
2
Monitor a negative voltage input from a sensor attached to the machine and
use overheat protection.
3
Monitor a positive voltage input from a sensor attached to the machine and
use overheat protection.
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.X