10.3 Alarm Message List
10-7
0040 MEMORY ERROR
(CPU BOARD RAM)
[Decimal Data]
Memory (RAM) error
Data stands for an error circuit board
1:XCP01 circuit board
2:XSP01 circuit board
10:XCP02 circuit board (#1-0)
11:XCP02 circuit board (#1-1
12:XCP02 circuit board (#1-2)
20:XCP02 circuit board (#2-0)
21:XCP02 circuit board (#2-1)
22:XCP02 circuit board (#2-2)
(Note)
XCP02 circuit board (#
.
-
"
)
.
:Slot NO.
"
:0
)
XCP02 circuit board (main
1
)
Sub-board1(connector CNSL side)
2
)
Sub-board2(connector CNET side)
50:WRCA01 circuit board (#1)
51:WRCA01 circuit board (#2)
52:WRCA01 circuit board (#3)
53:WRCA01 circuit board (#4)
54:WRCA01 circuit board (#5)
55:WRCA01 circuit board (#6)
(Note)
WRCA01 circuit board (#
.
)
The setting value of rotary switch on the
WRCA01 circuit board is
.
-1)
• Replace the circuit board.
• When the XCP01 circuit board is
replaced, consult a YASKAWA represen
tative.
0050 MEMORY
ERROR(PCI-BUS
COMMON RAM)
[Decimal Data]
A error occurred in PCI bus shared RAM of
the CPU rack or shared RAM between cir-
cuit boards.
Data stands for an error circuit board
10:XCP02 circuit board (#1-0)
11:XCP02 circuit board (#1-1
12:XCP02 circuit board (#1-2)
20:XCP02 circuit board (#2-0)
21:XCP02 circuit board (#2-1)
22:XCP02 circuit board (#2-2)
(Note)
XCP02 circuit board (#
.
-
"
)
.
:Slot NO.
"
:0
)
XCP02 circuit board (main
1
)
Sub-board1(connector CNSL side)
2
)
Sub-board2(connector CNET side)
Replace the circuit board.
Alarm Message List
Alarm
Number
Message Cause Remedy

Table of Contents

Related product manuals