EasyManua.ls Logo

YASKAWA YR-UP6-A00 - Page 400

YASKAWA YR-UP6-A00
561 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10.3 Alarm Message List
10-10
0400 PARAMETER
TRANSMISSION
ERROR
[Decimal Data]
• The connection of communication cable
for servopack was not completed.
• The connection of communication cable
for servopack was not cut.
• The connection of terminal connector is
not completed.
• The terminal connector is unusual.
• The circuit board was out of order. (The
terminal connector is equipped 1 for a sys-
tem).
Data stands for an error circuit board
50:WRCA01 circuit board (#1
51:WRCA01 circuit board (#2
52:WRCA01 circuit board (#3
53:WRCA01 circuit board (#4
54:WRCA01 circuit board (#5
55:WRCA01 circuit board (#6
(Note)
WRCA01 circuit board (#
.
)
The setting value of rotary switch on the
WRCA01 circuit board is (
.
-1)
• Check the connection of communication
cable for servopack. (XCP01
(
CN05 -
WRCA(#*)
(
CN10 cable,
WRCA
(
CN10(#*) - WRCA
(
CN10(#*
cable
• Replace the communication connector
for servopack.
• Check the connection of the terminal
connector (WRCA
(
CN10(#*)).
• Replace the terminal connector.
• Replace the circuit board.
0410 MODE CHANGE
ERROR
[Decimal Data]
An error occurred in process of change to
normal operation mode.
Data stands for an error circuit board
10:XCP02 circuit board (#1-0)
11:XCP02 circuit board (#1-1)
12:XCP02 circuit board (#1-2)
20:XCP02 circuit board (#2-0)
21:XCP02 circuit board (#2-1)
22:XCP02 circuit board (#2-2)
(Note)
XCP02 circuit board (#
.
-
"
)
.
:Slot NO.
"
:0
)
XCP02 circuit board (main)
1
)
Sub-board1(connector CNSL side)
2
)
Sub-board2(connector CNET side
50:WRCA01 board (#1)
51:WRCA01 board (#2)
52:WRCA01 board (#3)
53:WRCA01 board (#4)
54:WRCA01 board (#5)
55:WRCA01 board (#6)
(Note)
WRCA01 circuit board (#
.
)
The setting value of rotary switch on
WRCA01 circuit board is (
.
-1)
<Data:10-21>
• Insert the circuit board in the CPU rack
fast.
• Replace the circuit board.
<Data:50-55>
• Check the connection of communication
cable for servopack. (XCP01
(
CN05 -
WRCA(#*)
(
CN10 cable,
WRCA
(
CN10(#*) - WRCA
(
CN10(#*
cable
• Replace the communication connector
for servopack.
• Check the connection of the terminal
connector (WRCA
(
CN10(#*)).
• Replace the terminal connector.
• Replace the circuit board.
0500 SEGMENT PROC
NOT READY
An error occurred in communication
between XCP01 circuit board and WRCA01
circuit board.
• Turn the power off then back on.
• If the error occurs again, contact your
YASKAWA representative.
0900 WATCHDOG TIMER
ERROR
(XCP01)
[Decimal Data]
An insertion error of the XCP01 circuit board
or defective circuit board.
• Insert the circuit board in the CPU rack
fast.
• Replace the circuit board.
• If the error occurs again, contact your
YASKAWA representative.
Alarm Message List
Alarm
Number
Message Cause Remedy

Table of Contents

Related product manuals