10.3 Alarm Message List
10-22
1312 AMPLIFIER OVER-
LOAD
(MOMENT)
Robot/Station
[Axis Data]
The servopack (amplifier) current displayed
by axis data exceeded rated current for a
long time (a few seconds - a few minutes). It
may have burned the servopack.
• The wrong wiring, the breaking of the
UVW wire for the motor
• The type of motor was not correct.
• The motor was moved by external power.
• It interfered with an outside equipment.
• Defective WRCA01, WRCF01 circuit board
• Defective amplifier
• Defective motor (encoder)
• Check whether the robot interferes with
the outside equipment. If the robot inter-
feres, remove the cause.
• Check the connection of UVW wire of
motor again. And check the breaking of
the wire.
• There is a possibility the robot moves by
extra load. Check the motion status of
robot again and reduce the teaching
speed. Then confirm the reoccurrence.
<Error in robot axis>
Check that the type of motor is the same
as the one described in the manual. If
the type is not correct, replace it with th
correct motor.
<Error in external axis>
Check that the type of motor set by sys-
tem configuration is the same as the
actual installed one. If set data by sys-
tem configuration is correct, replace
installed motor with correct one. If set
data by system configuration is not cor-
rect, set the correct system configura-
tion.
• If the error occurs again, replace
WRCA01 and/or WRCF01 circuit board.
• Replace the amplifier, motor for axis
where the error occurred.
1313 MOTOR ERROR
Robot/Station
[Axis Data]
The motor was driven recklessly. This erro
occurred when the motor moved in reverse
for the forward instruction.
• Incorrect wiring of the UVW wire for the
motor
• The type of motor was not correct.
• Defective WRCA01, WRCF01 circuit board
• Check the connection of UVW wire of
motor again.
<Error in robot axis>
Check that the type of motor is same as
the one described in the manual. If the
type is not correct, replace it with correct
motor.
<Error in external axis>
Check that the type of motor set by sys-
tem configuration is same as actual
installed one. If set data by system con
figuration is correct, replace installed
motor with correct one. If set data by sys-
tem configuration is not correct, set the
correct system configuration.
• If the error occurs again, replace
WRCA01 and/or WRCF01 circuit board.