DELIVERY AND STORAGE
To ensure consistent quality and maximum reliability,
all AHUs are tested and inspected before leaving the
factory.
Short Term
Indoor AHUs: Under no circumstances
should outdoor storage be used.
• Remove of ventilate wrapping to prevent
condensation.
Outdoor AHUs: Recover AHUs after in-
spection or use tarps during storage.
Short term storage is six months or less from date of
shipment. Storage maintenance during this time is usu-
ally limited to the following:
• Rotate fans every four weeks, starting on the de-
livery date to prevent moisture from damaging
the bearing.
• If the AHUs are going to be stored out-of-doors,
prior to installation, special care must be taken to
cover and protect the AHUs from:
• Dust
• Rain and snow
• Rodents
• Construction vehicles and personnel.
• Condensation / Ventilation required
• Protect all parts and porous materials from rain
and other sources of moisture. Decontaminate or
replace parts as needed to make sure microbial
growth is not introduced to the AHU.
• StoretheAHUona rm,atsurface toprevent
distortion. Block the AHU off the ground to pro-
tect components from water or ground moisture.
SECTION 3 - HANDLING, STORAGE, AND INSTALLATION
Rigging and lifting should only be done by a professional rigger in accordance with a written rig-
ging and lifting plan. The most appropriate rigging and lifting method will depend on job specic
factors, such as the rigging equipment available and site needs. Therefore, a professional rigger
must determine the rigging and lifting method to be used, and it is beyond the scope of this manual
to specify rigging and lifting details.