Symbologies 11 - 3
Decode UPC/EAN/JAN Supplementals
(2 and 5 digits)
16 10h Ignore 11-13
User-Programmable Supplementals
Supplemental 1:
Supplemental 2:
579
580
F1h 43h
F1h 44h
000 11-16
UPC/EAN/JAN Supplemental Redundancy 80 50h 10 11-16
Decode UPC/EAN/JAN Supplemental
AIM ID
672 F1h A0h Combined 11-17
Transmit UPC-A Check Digit 40 28h Enable 11-18
Transmit UPC-E Check Digit 41 29h Enable 11-18
Transmit UPC-E1 Check Digit 42 2Ah Enable 11-19
UPC-A Preamble 34 22h System Character 11-20
UPC-E Preamble 35 23h System Character 11-21
UPC-E1 Preamble 36 24h System Character 11-22
Convert UPC-E to A 37 25h Disable 11-23
Convert UPC-E1 to A 38 26h Disable 11-23
EAN/JAN Zero Extend 39 27h Disable 11-24
UCC Coupon Extended Code 85 55h Disable 11-24
Coupon Report 730 F1h DAh New Coupon
Format
11-25
UPC Reduced Quiet Zone 1289 F8h 05h 09h Disable 11-25
Code 128
Code 128 8 08h Enable 11-26
Set Lengths for Code 128 209, 210 D1h, D2h 1 - 55 11-26
GS1-128 (formerly UCC/EAN-128) 14 0Eh Enable 11-27
ISBT 128 84 54h Enable 11-28
ISBT Concatenation 577 F1h 41h Autodiscriminate 11-29
Check ISBT Table 578 F1h 42h Enable 11-30
ISBT Concatenation Redundancy 223 DFh 10 11-30
Code 128 <FNC4> 1254 F8h 04h E6h Honor 11-31
Table 11-1 Symbology Parameter Defaults (Continued)
Parameter
Parameter
Number
1
SSI Number
2
Default
Page
Number
1. Parameter number decimal values are used for programming via RSM commands.