EasyManua.ls Logo

Zte ZXR10 8900 Series - Data Output; Configuring IPFIX; Basic Configuration; EnablingDisabling IPFIX Module

Zte ZXR10 8900 Series
186 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter18IPFIXConguration
DataOutput
Aftercollectingdataowsinnetwork,networkdevicealwaysout-
putsthemtoNMserver .IPFIXsupportstooutputdatatomultiple
NMservers.Generally,dataareoutputtotwoservers:master
serverandslaveserver .
IPFIXadoptstemplate-baseddataoutputmode.IFPIXsupportsto
sendtemplateeveryafewpacketsoratacertaininterval.Packet
templatespeciestheformatandlengthofpacketsinsubsequent
dataows,andserverresolvessubsequentdataowsaccording
totemplate.
ConfiguringIPFIX
BasicConfiguration
Enabling/DisablingIPFIXModule
CommandFunctions
ZXR10(config)#ipstream{enable|disable}Thisenables/disablesIPFIX
module.
SettingIPFIXMemoryEntries
CommandFunctions
ZXR10(config)#ipstreamcacheentries<number>
Thissetsthenumberofdata
owentriesstoredinIPFIX
module,4096bydefault.
SettingAgingTimeofActiveStream
CommandFunctions
ZXR10(config)#ipstreamcacheactinve<number>
Thissetsagingtimeofactive
stream.
Asforlongtimeactivestream,incaseitexceedsthesetaging
time,thisdataowwillageout,inminutes,30minutesbydefault.
CondentialandProprietaryInformationofZTECORPORATION163

Table of Contents

Other manuals for Zte ZXR10 8900 Series

Related product manuals