Chapter 22 GARP Commands
Ethernet Switch CLI Reference Guide
98
22.3 Command Examples
In this example, the administrator looks at the Switch’s GARP timer settings and decides to
change them. The administrator sets the Join Timer to 300 milliseconds, the Leave Timer to
800 milliseconds, and the Leave All Timer to 11000 milliseconds.
sysname# show garp
GARP Timer
------------------------
Join Timer :200
Leave Timer :600
Leave All Timer :10000
sysname# configure
sysname(config)# garp join 300 leave 800 leaveall 11000
sysname(config)# exit
sysname# show garp
GARP Timer
------------------------
Join Timer :300
Leave Timer :800
Leave All Timer :11000