6.35 The SSL Inspection Screens
The Zyxel Device uses SSL Inspection to decrypt SSL traffic, sends it to the Security Service engines for
inspection, then encrypts traffic that passes inspection and forwards it. You must enable SSL Inspection if
you want to use Content Filtering 2.0 Safe Search.
Click Monitor > Security Statistics > SSL Inspection > Summary to display the following screen.
Figure 142 Monitor > Security Statistics > SSL Inspection > Summaryt
The following table describes the labels in this screen.
Table 67 Monitor > Security Statistics > SSL Inspection > Summary
LABEL DESCRIPTION
Collect Statistics Select this check box to have the Zyxel Device collect SSL Inspection statistics.
The collection starting time displays after you click Apply. All of the statistics in this
screen are for the time period starting at the time displayed here. The format is year,
month, day and hour, minute, second. All of the statistics are erased if you restart the
Zyxel Device or click Flush Data. Collecting starts over and a new collection start time
displays.
Apply Click Apply to save your changes back to the Zyxel Device.
Reset Click Reset to return the screen to its last-saved settings.
Refresh Click this button to update the report display.
Flush Data Click this button to discard all of the screen’s statistics and update the report display.
Status
Maximum Concurrent
Sessions
This shows the maximum number of simultaneous SSL Inspection sessions allowed for
your Zyxel Device model.
Concurrent Sessions This shows the actual number of simultaneous SSL Inspection sessions in progress.
Summary
Total SSL Sessions This is the total of SSL sessions inspected and number of sessions blocked and number
of sessions passed since data was last flushed or the Zyxel Device last rebooted after
Collect Statistics was enabled.
Sessions Inspected This shows the total number of SSL sessions inspected since data was last flushed or the
Zyxel Device last rebooted after Collect Statistics was enabled