• Manual Answering – the device rings to signal incoming calls and the user can press a button to pick up.
• Automatic – the device picks up incoming calls automatically.
Pick up in – this parameter is only active when the Automatic pickup mode is enabled. The call is picked up
automatically after the preset timeout.
Reject Calls in DND Mode – if this function is activated, the device reject calls in the Do not Disturb mode.
The function can be used for immediate call redirection at absence to a mobile phone call, for example.
DND Mode for Doorbell Button – if this function is activated, the device shall not ring when the doorbell
button is pressed.
Do Not Disturb Mode with Time Profile – choose one or more time profiles to be applied to the DND mode.
Set the time profiles in Directory > Time profiles (p. 31).
Click the icon to set the selection from predefined profiles or manual setting of a time profile for the
given element.
Outgoing Calls
Connecting Time Limit – set the maximum outgoing call connection timeout after which the calls are
automatically terminated. If the calls are routed to the GSM network via GSM gateways, you are advised to
set a value higher than 20 s.
Ring time limit – set the maximum call setup and ringing time in which all outgoing calls are automatically
terminated. If the calls are routed to the GSM network via GSM gateways, you are advised to set a value
longer than 20 s. Minimum value: 1 s, maximum value: 600 s. Set 0 to disable the time parameter.
Call Log
Save Image during Call – if enabled, one or more snapshots are automatically taken from each video call
and saved into the call log (depending on the device type and setting). More images can be taken manually
during a call on some devices.
CAUTION
If the Save Image during Call function is disabled, all the snapshots will be deleted but the
call logs will be preserved.
Advanced Settings
Starting RTP Port – set the initial local RTP port in the range of 64 ports used for audio and video
transmission. The default value is 4900 (i.e. the range is 4900–4963). The parameter applies to both the SIP
accounts.
RTP Timeout – set the audio stream RTP packet receiving timeout during a call. If this limit is exceeded
(RTP packets are not delivered), the call will be terminated by the device. Enter 0 to disable this parameter.
The parameter applies to both the SIP accounts.
Extended SIP Logging – allow SIP telephony details to be recorded in syslog (for troubleshooting purposes
only).).
SIP 1 / SIP 2
2N Indoor Compact allows two independent SIP accounts to be configured. Thus, the intercom can be
registered under two phone numbers at the same time, with two different SIP exchanges, for example.
Both the SIP accounts process incoming calls equivalently. Outgoing calls are primarily processed using
Software Configuration