453D SYSTEMS, INC.
Manufacturing launch warnings
After clicking on the
button, if there are some warnings, the
"Manufacturing launch warnings" message will appear:
This is a warning information to indicate:
Lens cleaner lter timer compared to the recommended
interval replacement,
Powder selected on the printer conguration (see section "Conguration" on page 47) compared to the powder
dened on the FAB3 manufacturing le.
Type of powder (reactive or non-reactive) compared to the type of gas, both dened on the printer conguration
(see section "Conguration" on page 47).
Current oxygen value compared to the “Minimum O2 threshold to launch a manufacturing” setting (see "Oxygen
tab" paragraph of the section "Conguration" on page 47),
Scanner head sensor state.
Base plate clamping state.
1. Select Quit (C), then x all warnings before continuing.
2. Click on either Validate to conrm (A), or on one of the Delay start functions (B) (see section "Delay start function" on
page 44) or on Quit (C) to cancel.
To overcome O2 level variation around the fume safety setting, the job will start only if the oxygen level is
lower than 90% of the fume safety setting.
Interrupt a job
During the manufacturing, it is possible to interrupt the job by clicking the pause button
. When activated:
The Cycle interruption message will be displayed.
The printer will nish the current layer sintering, will then proceed to the next layering cycle without sintering. The
operator will have to:
Click on
to continue the job, or
Click on
to completely stop the manufacturing.