463D SYSTEMS, INC.
3
Information area
ATMOSPHERE
Gas (mode of the gas supplied): REGUL (regulation around an oxygen target value), DIRECT (continuous injection of
gas at a constant rate), OFF (no gas injection),
Status of the gas valve indicator : if green, the valve is opened,
O2 value: current oxygen level value in PPM (particles per million) on the manufacturing chamber,
O2 setpoint: oxygen level target value,
Enclosure pressure: current pressure value in the manufacturing chamber,
Enclosure temperature: current temperature value on the manufacturing chamber.
LENS CLEANER
Turbine: state of the lens cleaner blower (turbine). If green/white, the blower is operating/not operating,
Setpoint: setpoint of the blower operating, in %,
Differential pressure : [Outlet Pressure – Inlet Pressure] of the external lter.
PART
Clamping: status of the base plate clamp. If green/white, clamping is ON/OFF,
Available powder: the height of the powder available in the feeding piston in mm,
Zero sintering: the zero position of the sintering piston in mm.
Loaded powder: name of the powder. Corresponds to the value set in the Conguration menu (see section
"Conguration" on page 47).
LASER/OPTIC
Defocus: defocusing value in mm (relative position of the sintering piston compare to the zero sintering position),
Laser power: current Laser power, in %.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the 3D Systems ProX DMP 200 and is the answer not in the manual?

3D Systems ProX DMP 200 Specifications

General IconGeneral
Brand3D Systems
ModelProX DMP 200
Category3D Printers
LanguageEnglish

Related product manuals