463D SYSTEMS, INC.
3
Information area
ATMOSPHERE
Gas (mode of the gas supplied): REGUL (regulation around an oxygen target value), DIRECT (continuous injection of
gas at a constant rate), OFF (no gas injection),
Status of the gas valve indicator : if green, the valve is opened,
O2 value: current oxygen level value in PPM (particles per million) on the manufacturing chamber,
O2 setpoint: oxygen level target value,
Enclosure pressure: current pressure value in the manufacturing chamber,
Enclosure temperature: current temperature value on the manufacturing chamber.
LENS CLEANER
Turbine: state of the lens cleaner blower (turbine). If green/white, the blower is operating/not operating,
Setpoint: setpoint of the blower operating, in %,
Differential pressure : [Outlet Pressure – Inlet Pressure] of the external lter.
PART
Clamping: status of the base plate clamp. If green/white, clamping is ON/OFF,
Available powder: the height of the powder available in the feeding piston in mm,
Zero sintering: the zero position of the sintering piston in mm.
Loaded powder: name of the powder. Corresponds to the value set in the Conguration menu (see section
"Conguration" on page 47).
LASER/OPTIC
Defocus: defocusing value in mm (relative position of the sintering piston compare to the zero sintering position),
Laser power: current Laser power, in %.

Table of Contents