b) Results Detailpage
3M™ Attest™ Auto-reader 390 Results Detail
Status
History
Print
Result
Start Time
Well# and Configuration
390 Serial Number
Control?
BI Lot#
Load#
Sterilizer#
Technician
Chemical Integrator?
Implant?
Cycle Parameters
Notes
Yes
2015-02TI
n/a
n/a
sdf
n/a
n/a
n/a
Daily control BI
+
2012-10-18 08:08:39
#6 1292
200004
This page provides an individual record for an incubated BI. For complete documentation, 
the user may print a hard copy and/or save the record as an electronicfile.
Note 1: The top four rows (highlighted in green) are populated automatically by the 
3M™Attest™ Auto-reader390and cannot be changed by the user. The remaining rows 
are completed by the user to satisfy the documentation requirements of theirfacility.
Note 2: The Results Detail page refreshes less frequently that the Status page. Until the BI 
result is available, the Results Detail page displays remaining minutes of incubation in the 
resultsfield.
c) Historypage
Status
History
3M™ Attest™ Auto-reader 390
Well# and Configuration
#9 1292
#4 1291
#8 1292
#3 1291
#7 1292
#2 1291
#1 1291
#6 1292
Start Time
2012-10-18 14:31:33
2012-10-18 14:23:10
2012-10-18 11:17:04
2012-10-18 11:16:59
2012-10-18 09:10:03
2012-10-18 09:10:02
2012-10-18 08:09:31
2012-10-18 08:08:39
Result
---
---
–
–
–
–
+
+
ID
1
2
3
4
5
6
7
8
The 3M™Attest™ Auto-reader390stores results for the last 100incubated BIs on 
embedded software. The 3M™Attest™ Auto-reader390Web App History page provides 
a summary of these last 100results.
d) Configurationpage
This page allows the configuration of the 3M™Attest™ Auto-reader390’s network and 
language settings from the 3M™Attest™ Auto-reader390WebApp.
Documenting BI Results using the 3M™Attest™ 
Auto-reader390WebApp
Status
History
3M™ Attest™ Auto-reader 390
AT TEST 1291 AT TEST 1292
1 2 3 4 5
+––59 174
6 7 8 9 10
+– –
SN
200004
2012-10-18 15:27
1.   Open the Results Detailpage
After inserting a new 3M™Attest™ Rapid Readout BI in the 3M™Attest™ 
Auto-reader390, it is a best practice to open the 3M™Attest™ Auto-reader390Web 
App Results Detail page for that BI by clicking on the appropriate well number from the 
Statuspage.
2. Enter the specific information for that BI (e.g., BI Lot #, sterilizer/load number, 
Technician name, etc.) in the provided editable fields. Use the Notes section to capture 
information not prescribed in the provided row titles; for example, you may wish to use 
this field to record loaditems.
3M™ Attest™ Auto-reader 390 Results Detail
Status
History
Print
Result
Start Time
Well# and Configuration
390 Serial Number
Control?
BI Lot#
Load#
Sterilizer#
Technician
Chemical Integrator?
Implant?
Cycle Parameters
No
2015-01DS
1
1
sdf
accept
no
270F 4min
54
2012-10-18 15:26:42
#2 1291
200004
3.  The entered information is saved automatically to temporary web browser storage on 
the user’s PC every 60seconds, or by leaving the Results Detailspage.
4. Print/File. Once the BI result is available, print or file the Results Detail page to create 
a record. The page may be physically printed and/or saved as an electronicfile.
Important! Data is only stored for the last 100incubatedBIs.
Embedded software in the 3M™Attest™ Auto-reader390saves the data from the 
auto-populated (i.e., green highlighted) fields. The application relies on the temporary 
storage in the user’s web browser to save the data in the user-populated fields. In both 
cases, data is only stored for the last 100records, i.e., the 101st incubated BI will erase 
the information saved for the 1st incubated BI. To retain the Results Detail information for 
future reference it is best practice to print the page or save to an electronic file as soon as 
the BI result isavailable.
Using the BI HistoryPage
Status
History
3M™ Attest™ Auto-reader 390
Well# and Configuration
#9 1292
#4 1291
#8 1292
#3 1291
#7 1292
#2 1291
#1 1291
#6 1292
Start Time
2012-10-18 14:31:33
2012-10-18 14:23:10
2012-10-18 11:17:04
2012-10-18 11:16:59
2012-10-18 09:10:03
2012-10-18 09:10:02
2012-10-18 08:09:31
2012-10-18 08:08:39
Result
---
---
–
–
–
–
+
+
ID
1
2
3
4
5
6
7
8
To view or print an individual record, click on the ID number of the desired record to 
navigate to the Results Detail page for thatBI.
Note 1: Column 1, “ID” is the assigned ID number with ID 1representing the newest 
record and ID 100representing the oldest record. For convenience, all columns are 
sortable; to help find a particular record, simply click once on the column heading to sort 
in ascending order and click a second time to reverse theorder.
Note 2: The History page refreshes less frequently than the Status page. Until the BI result 
is available, the History page displays ••• in the Results column indicating incubation is 
stillin-process.
  Rendered on 5/8/2013 10:56:36 AM