Loading...
See section Ratings.
Current
3 kHz (typically)Switching frequency
DTC control: 500 m (1640 ft)Maximum recommended
motor cable length
Scalar control: 500 m (1640 ft)
Note: For restrictions due to EMC compatibility, see section EMC compliance
(IEC/EN 61800-3:2004) (page 198).
Longer motor cables cause a motor voltage decrease which limits the available
motor power. The decrease depends on the motor cable length and characteristics.
Contact ABB for more information. Note that a sine filter (optional) at the drive
output also causes a voltage decrease.
DC connection data
Capacitance (mF)ACS880-14-…
U
n
= 400 V
10.5246A-3
10.5293A-3
10.5363A-3
10.5442A-3
10.5505A-3
14.0585A-3
14.0650A-3
U
n
= 500 V
10.5240A-5
10.5260A-5
10.5302A-5
10.5361A-5
10.5414A-5
14.0460A-5
14.0503A-5
U
n
= 690 V
5.3142A-7
5.3174A-7
5.3210A-7
5.3271A-7
5.3330A-7
5.3370A-7
5.3430A-7
Control panel type
ACS-AP-W assistant control panel
194 Technical data