NoteAction
Small circular plate of the axis-2
sealing assembly tool, included in
Special toolkit for IP67 robots
(3HAC078203-001).
Fit the small circular plate of the axis-2 sealing
assembly tool and fix with three M6x75 screws.
6
xx2000002470
xx2000002471
Screw the screws, little by little and evenly, to
press the sealing into place.
7
Remove the assembly tool.8
Check that the sealing is undamaged and properly
fitted.
9
Refitting the swing support
NoteAction
Sealing ring, swing support side:
3HAC065676-001
Check the sealing ring.
Replace if damaged.
1
Screw: M4x12 12.9 Lafre
2C2B/FC6.9 (16 pcs)
Tightening torque: 3.8 Nm
xx2000001692
Continues on next page
Product manual - CRB 1300 305
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.4.2 Replacing the swing