Loading...
Securing the motor cabling
NoteAction
Screw: M4x8 12.9 Lafre
2C2B/FC6.9 (2 pcs)
Refit the cable bracket.1
Tightening torque: 2.6 Nm
xx2000001625
xx2000001624
Secure the FB2 cabling to the bracket with cable
strap.
2
Wrap the connectors and route the cablings up
into the lower arm.
3
Reconnecting the axis-2 motor connectors
NoteAction
xx2000001641
Insert the male header of the motor connectors
to the connector plate.
1
xx2000001640
Route and secure the cabling with a cable strap.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
2
Continues on next page
504 Product manual - CRB 1300
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.6.2 Replacing the axis-2 motor
Continued

Table of Contents