Parameters 429
SLSx.43 SLS4 trip limit
positive
Sets the SLS4 positive speed limit that trips
the drive.
Note: Variable SLS uses this limit as scaled.
See Defining the scaled SLS4 limit and
SLS4 trip limits on page 370.
0.0 rpm
0.0…35880.0 rpm Speed
SLSx.44 SLS4 output Sets the digital output for the SLS4 function.
Active when SLS4 function is active and the
motor speed is below the SLS4 limit (that is,
when the SLS4 monitoring is on).
None
None No output connected
DO X113:7 & X114:7 Redundant output X113:7 & X114:7
DO X113:8 & X114:8 Redundant output X113:8 & X114:8
DO X113:9 & X114:9 Redundant output X113:9 & X114:9
DO X113:7 Single output X113:7
DO X113:8 Single output X113:8
DO X113:9 Single output X113:9
DO X114:7 Single output X114:7
DO X114:8 Single output X114:8
DO X114:9 Single output X114:9
SLSx.47 Mute time for SLS4 Sets the SLS4 specific mute time for limit hit
situations.
This parameter is effective only with the safe
speed estimate.
0 ms
0…10000 ms
SLSx.51 Variable SLS output Sets the digital output for the Variable SLS
function. Active when Variable SLS function
is active and the motor speed is below the
Variable SLS limit (that is, when the Variable
SLS monitoring is on).
None
None No output connected
DO X113:7 & X114:7 Redundant output X113:7 & X114:7
DO X113:8 & X114:8 Redundant output X113:8 & X114:8
DO X113:9 & X114:9 Redundant output X113:9 & X114:9
DO X113:7 Single output X113:7
DO X113:8 Single output X113:8
DO X113:9 Single output X113:9
DO X114:7 Single output X114:7
DO X114:8 Single output X114:8
DO X114:9 Single output X114:9
Index Name/Value Description Factory
default