EasyManua.ls Logo

ABB FSO-21 - Page 428

ABB FSO-21
540 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
428 Parameters
SLSx.34 SLS3 output Sets the digital output for the SLS3 function.
Active when SLS3 function is active and the
motor speed is below the SLS3 limit (that is,
when the SLS3 monitoring is on).
None
None No output connected
DO X113:7 & X114:7 Redundant output X113:7 & X114:7
DO X113:8 & X114:8 Redundant output X113:8 & X114:8
DO X113:9 & X114:9 Redundant output X113:9 & X114:9
DO X113:7 Single output X113:7
DO X113:8 Single output X113:8
DO X113:9 Single output X113:9
DO X114:7 Single output X114:7
DO X114:8 Single output X114:8
DO X114:9 Single output X114:9
SLSx.37 Mute time for SLS3 Sets the SLS3 specific mute time for limit hit
situations.
This parameter is effective only with the safe
speed estimate.
0 ms
0…10000 ms
SLSx.41 SLS4 input Sets the digital input for the SLS4 function. None
None No input connected
DI X113:1 & X114:1 Redundant input X113:1 & X114:1
DI X113:2 & X114:2 Redundant input X113:2 & X114:2
DI X113:3 & X114:3 Redundant input X113:3 & X114:3
DI X113:4 & X114:4 Redundant input X113:4 & X114:4
DI X113:1 Single input X113:1
DI X113:2 Single input X113:2
DI X113:3 Single input X113:3
DI X113:4 Single input X113:4
DI X114:1 Single input X114:1
DI X114:2 Single input X114:2
DI X114:3 Single input X114:3
DI X114:4 Single input X114:4
SLSx.42 SLS4 trip limit
negative
Sets the SLS4 negative speed limit that trips
the drive.
Note: Variable SLS uses this limit as scaled.
See Defining the scaled SLS4 limit and
SLS4 trip limits on page 370.
0.0 rpm
-35880.0 …0.0 rpm Speed
Index Name/Value Description Factory
default

Table of Contents

Related product manuals