446 Parameters
SAFEIO.53 DO X113:7 diag
pulse on/off
Sets the diagnostic pulse of digital output
X113:7 on or off.
On
Off Diagnostic pulse off
On Diagnostic pulse on
SAFEIO.54 DO X113:8 diag
pulse on/off
Sets the diagnostic pulse of digital output
X113:8 on or off.
On
Off Diagnostic pulse off
On Diagnostic pulse on
SAFEIO.55 DO X113:9 diag
pulse on/off
Sets the diagnostic pulse of digital output
X113:9 on or off.
On
Off Diagnostic pulse off
On Diagnostic pulse on
SAFEIO.56 DO X114:7 diag
pulse on/off
Sets the diagnostic pulse of digital output
X114:7 on or off.
On
Off Diagnostic pulse off
On Diagnostic pulse on
SAFEIO.57 DO X114:8 diag
pulse on/off
Sets the diagnostic pulse of digital output
X114:8 on or off.
On
Off Diagnostic pulse off
On Diagnostic pulse on
SAFEIO.58 DO X114:9 diag
pulse on/off
Sets the diagnostic pulse of digital output
X114:9 on or off.
On
Off Diagnostic pulse off
On Diagnostic pulse on
SAFEIO.71 DO X113:7 logic
state
Sets the logic state of digital output X113:7. Active low
Active low Active state of the output is low voltage.
Active high Active state of the output is high voltage.
SAFEIO.72 DO X113:8 logic
state
Sets the logic state of digital output X113:8. Active low
Active low Active state of the output is low voltage.
Active high Active state of the output is high voltage.
SAFEIO.73 DO X113:9 logic
state
Sets the logic state of digital output X113:9. Active low
Active low Active state of the output is low voltage.
Active high Active state of the output is high voltage.
SAFEIO.74 DO X114:7 logic
state
Sets the logic state of digital output X114:7. Active low
Active low Active state of the output is low voltage.
Active high Active state of the output is high voltage.
SAFEIO.75 DO X114:8 logic
state
Sets the logic state of digital output X114:8. Active low
Active low Active state of the output is low voltage.
Index Name/Value Description Factory
default