HVC 450 kW E-Bus Charger Installation Guide
Revision: 1.2 COMPANY CONFIDENTIAL
Date released: 16-08-2018 Page 102 of 128
4
Wire 2
PE
X3
X4
ACS Control cable
1
Wire 1
ACS +24V
2
Wire 2
ACS -24V
3
GND (green/yellow)
GND
5
Wire 3
ACS Extend/Retract Out
6
Wire 4
ACS Magn Reed In
7
Wire 5
ACS Supply/Retract Out
8
Wire 6
ACS Retracted In
9
Wire 7
ACS Magn Supply Out
10
Wire 8
ACS GND_B
11
Wire 9
ACS Extended In
X4
EMO cable
13
Wire 1
EMO S1
15
Wire 2
EMO S1
14
Wire 3
EMO S2
16
Wire 4
EMO S2
X4
Beacon cable
17
Wire 1
Beacon RD
18
Wire 2
Beacon GN
19
Wire 3
Beacon BU
20
Wire 4
Beacon 24V
X4
Distance sensor cable
21
Wire 1
Distance Sensor +24V
23
Wire 2
Distance Sensor NO/NC
22
Wire 3
Distance Sensor GND
24
Wire 4
Distance Sensor Analog out
13. Tighten the connector screws.
5.17. Close the door of the ACS Control Module
Preconditions:
Key
1. Close the door (A).
2. Close the locks (B).