NoteAction
xx0800000335
Remove the bracket on the armhouse.4
Parts:
A: Tubular shaft unit
B: Attachment screws
C: Bracket, armhouse
xx0800000338
Remove the cable cover on the armhouse.5
Parts:
A: Signal lamp
B: Bracket
C: Cable cover, armhouse
Remove signal lamp if used.6
How to remove the motor cables from the
axis-3, axis-4, axis-5 and axis-6 motors
see section:
Removing motors on page 286
IRB 2600 Standard:
Continue the removal of the cable package
by disconnecting the motor cables of the
axis-3, axis-4, axis-5 and axis-6 motors.
7
How to remove the motor cables from
motors axes 3 and 4 see section:
Removing motors on page 286
IRB 2600ID:
Continue the removal of the cable package
by disconnecting the motor cables of mo-
tors axes 3 and 4.
8
See section:
Replacing the cable harness in the
upper arm - IRB 2600ID on page 221
IRB 2600ID:
Remove the cable package in the upper
arm.
9
Product manual - IRB 2600 205
3HAC035504-001 Revision: G
© Copyright 2009-2015 ABB. All rights reserved.
4 Repair
4.3.1 Removing the complete cable harness
Continued