Removing the brake release unit
Use this procedure to remove the brake release unit.
NoteAction
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot
working area.
1
A
B
C
xx0800000456
Remove the base cover.2
Parts:
A: Base
B: Base cover
C: Attachment screws M6x16
quality 8.8-A2F (6 pcs)
See the figure in:
Connectors on push-button unit on
page 237
Disconnect connectors X8, X9 and X10 from
the brake release unit.
3
See the figure in:
Location of brake release unit on
page 237
Remove the nuts securing the brake release
unit.
4
Remove the brake release unit.5
Continues on next page