Loading...
Deciding calibration routine
Decide which calibration routine to be used, based on the information in the table.
Depending on which routine is chosen, action might be required prior to beginning
the repair work of the robot, see the table.
NoteAction
Decide which calibration routine to use for
calibrating the robot.
Reference calibration. External cable
packages (DressPack) and tools can
stay fitted on the robot.
Fine calibration. All external cable
packages (DressPack) and tools
must be removed from the robot.
1
Follow the instructions given in the refer-
ence calibration routine on the FlexPendant
to create reference values.
If the robot is to be calibrated with refer-
ence calibration:
Find previous reference values for the axis
or create new reference values. These val-
ues are to be used after the repair proced-
ure is completed, for calibration of the ro-
bot.
Creating new values requires possibility to
move the robot.
Read more about reference calibration for
Axis Calibration in Reference calibration
routine on page 799.If no previous reference values exist, and
no new reference values can be created,
then reference calibration is not possible.
Read more about reference calibration for
Pendulum Calibration in Operating manu-
al - Calibration Pendulum.
If the robot is to be calibrated with fine
calibration:
Remove all external cable packages
(DressPack) and tools from the robot.
Removing the motor
These procedures describes how to remove the motor.
Preparations before removing the axis-2 motor
NoteAction
Decide which calibration routine to use,
and take actions accordingly prior to begin-
ning the repair procedure.
1
See Draining the axis-2 gearbox on
page 166.
Drain the oil from the gearbox.2
Jog the robot to the calibration position.3
DANGER
Secure the weight of the lower arm with a
lock screw, before releasing the brakes on
the axis-2 motor as well as before removing
the axis-2 motor or the axis-2 gearbox.
4
Continues on next page
Product manual - IRB 6700 519
3HAC044266-001 Revision: N
© Copyright 2013 - 2018 ABB. All rights reserved.
4 Repair
4.7.2 Replacing the axis-2 motor
Continued

Table of Contents