EasyManua.ls Logo

ABB IRB 6700 Series - Page 549

ABB IRB 6700 Series
846 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NoteAction
xx1200001020
Make sure the o-ring is seated in the groove.
Tip
Lubricate the o-ring with some grease for a better
fitting in the groove.
4
xx1200001135
If the motor is a new spare part, remove the cover.5
Tightening torque, transparent
plug: 25 Nm ±10%.
Foundry Plus:
Valid for axis-2, axis-3, axis-4 and axis-6 motors.
6
Tightening torque, protection filter:
10 Nm ±10%.
xx1600000576
If the motor is a new spare part, the evacuation
hole protection filter must be replaced with a
transparent plug/sight glass (enclosed with the
spare part delivery). Remove the protection filter
and install the transparent plug/sight glass.
On the axis-6 motor there are two protection filters
that must be replaced with transparent plugs/sight
glasses.
xx1800000102
Transparent plug
(Foundry Plus).
xx1800000101
Protection filter (Stand-
ard).
Securing the axis-4 motor
NoteAction
Guide pin, M8x150: 3HAC15520-2Apply two guide pins in opposite holes.1
Always use guide pins in pairs.
Continues on next page
Product manual - IRB 6700 549
3HAC044266-001 Revision: N
© Copyright 2013 - 2018 ABB. All rights reserved.
4 Repair
4.7.4 Replacing the axis-4 motor
Continued

Table of Contents

Related product manuals