EasyManua.ls Logo

ABB IRB 6710 - Page 142

ABB IRB 6710
640 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NoteAction
Required oil level: 53-63 mm below the
machined surface at the oil plug hole
Inspect the oil level through the inspection
hole.
Tip
If there is a risk of debris falling into the
gear when opening the oil plug for inspec-
tion, it is instead recommended to use the
vent hole for oil level inspection:
xx2200002147
6
xx2200001754
Required oil level at vent hole is: 24 mm ±
5 mm below the oil plug hole
xx2300000001
CAUTION
The oil level sinks when the oil fills all cav-
ities in the gearbox. Wait until the oil stops
sinking, before measuring the oil level.
Remove the oil dispenser and refit the
protective cap to the nipple.
7
Continues on next page
142 Product manual - IRB 6710
3HAC085695-001 Revision: A
© Copyright 2023 ABB. All rights reserved.
4 Maintenance
4.4.2 Changing the oil in axis-1 gearbox
Continued

Table of Contents

Related product manuals