NoteAction
xx1000001310
Locate the calibration mark on the turning disk
and place the turning disk at the tilthouse so
that the calibration mark matches the calibration
scale at the tilthouse.
The hole pattern of the turning disk allows the
turning disk to be fitted in three different rotated
positions. Matching the calibration marks
guarantees that the turning disk is fitted at the
correct turn, provided that the axis 6 was set
in calibration position before the turning disk
was removed!
2
xx1400000995
Foundry Plus:
Apply Loctite 574 flange sealant on the contact
surface.
3
xx1000001290
Attachment screws: M10x25 quality
12.9 (33 pcs).
Tightening torque:
50 Nm.
Reused screws may be used, providing
they are lubricated as detailed in sec-
tion Screw joints on page 385 before fit-
ting.
Secure the turning disk with its attachment
screws.