NoteAction
xx1000001114
With the help of the ball bearing puller carefully
remove the balancing device from its upper and
lower attachments.
11
Remove the balancing device and put it in a
safe place.
12
xx1000001116
Remove upper and lower spacer rings and
support washers (2+2 pcs).
13
Remove residual grease and sealing compound.14
Refitting, balancing device
use this procedure to refit the balancing device.
NoteAction
Check the bearings. Replace if needed.1
Continues on next page