NoteAction
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot working
area.
2
xx1000001092
Remove the motor cover to get access to the
connectors on top of the motor.
3
xx1000001094
Remove the cable gland cover at the cable exit
of the motor.
Note
Make sure the gasket is undamaged! Replace
if damaged.
4
Disconnect all connectors beneath the motor
cover.
5
Connect to connector R2.MP1
+ : pin 2
-: pin 5
In order to release the brake, connect the 24
VDC power supply.
6
xx1000001090
Remove the attachment screws of the motor.
Use the bits extension.
7
Continues on next page