Installation, signal lamp
Use this procedure to install the signal lamp to the robot.
NoteAction
See figure Signal lamp kit on
page 85.
Fit the signal lamp bracket to the tilthouse, with
two attachment screws.
1
See figure Signal lamp kit on
page 85.
Fit the signal lamp to the bracket, with two attach-
ment screws.
2
See Electrical installation, signal
lamp on page 86.
If not already connected, connect the signal lamp
to the axis 6 motor.
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot working
area.
3
See figure Signal lamp kit on
page 85.
Arrange the signal cable in a loop at the signal
cable bracket with two cable straps.
4
Electrical installation, signal lamp
Use this procedure to connect the signal lamp to the axis 6 motor. The instruction
requires that the signal lamp is already mounted to the tilthouse.
NoteAction
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot working
area.
1
See figure Location of signal lamp,
upper arm on page 84.
Remove the motor cover by unscrewing the four
attachment screws.
2
Disconnect the motor connectors.3