EasyManua.ls Logo

ABB Terra 124 - Maintenance schedule for the service engineer

ABB Terra 124
117 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Output current in function of output voltage (two charge sessions)
CCS (200A) CHAdeMO (200A)CCS High Current (400A)
output voltage (V)
100 200 300 400 500 600 700 800 900 1000
0
50
150
150
200
250
300
350
400
450
500
Output current (A)
Charger Capacity
Voltage [V] Current [A] Power [kW]
150 0 0
150 480 72
200 600 120
300 600 180
400 450 180
600 300 180
800 225 180
920 196 180
Technical data
9AKK108466A3703-EN | 001 109