10.11 Cable management system specifications
A Clamp
X Distance from the cable exit point
Y Distance from the connector
Cable type
(A)
Length Clamp
model
Distance
from the
cable exit
point (X)
Distance
from the
connector
(Y)
Counter-
weights
[m] [ft]
CCS-1
200A
4 13 BP-1394-2
64A
50 % 50 % 3
CCS-1
200A
6 20 BP-1394-2
64A
30 % 70 % 4
CCS-1
200A
8 26 BP-1394-2
64A
See *
CCS-1
400A
4 13 BP-1394-2
82A
50 % 50 % 4
CCS-1
400A
6 20 BP-1394-2
82A
30 % 70 % 5
CCS-1
400A
8 26 BP-1394-2
82A
See *
CHAdeMO
200 A
4 13 BP-1394-3
55A
50 % 50 % 5
CHAdeMO
200 A
6 20 BP-1394-3
55A
30 % 70 % 5
CHAdeMO
200 A
8 26 BP-1394-3
55A
See *
* The maximum cable length supported by the ABB cable retraction system is 6
m (20 ft). If the EVSE is equipped with a cable longer than 8 m (26 ft) the EVSE
is not compliant with NEC 625.17. An external cable management system must be
installed to comply with the standard.
Technical data