10.17.2 Terra 94
Parameter Specification
DC output power on one EV charge cable Maximum 90 kW
Simultaneous DC on two outlets No. One DC output operates at a time.
Maximum DC output current CCS: 200 A or 300 A (high current model)
CHAdeMO: 200 A
Output current in function of output voltage
0
100
200
300
400
500
600
100 200 300 400 500 600 700 800 900 1000
Output current (A)
output voltage (V)
CCS (200A) CHAdeMO (200A)CCS High Current (300A)
Charger Capacity
Voltage [V] Current [A] Power [kW]
150 0 0
150 240 36
200 300 60
300 300 90
400 225 90
600 150 90
800 113 90
920 90 90
Technical data
9AKK108466A3703-EN | 001 97